SW500 Technical Information
Application |
Interrupted Uninterrupted |
|
Thermal Current Rating |
- |
500A |
Intermittent Current Rating: |
||
30% Duty |
- |
915A |
40% Duty |
- |
790A |
50% Duty |
- |
705A |
60% Duty |
- |
645A |
70% Duty |
- |
600A |
Rated Fault Current Breaking Capacity (Icn) 5ms Time Constant:(In accordance with UL583*) |
||
Blowouts |
- |
|
No Blowouts |
- |
|
Rated Fault Current Breaking Capacity (Icn) Resistive Load:(In accordance with UL508*) |
||
Blowouts |
- |
|
No Blowouts |
750A at 60V D.C. |
|
Maximum Recommended Contact Voltages |
||
Blowouts |
- |
- |
No Blowouts |
- |
60V |
Typical Voltage Drop per pole across New Contacts at 500A |
50mV |
|
|
||
Mechanical Durability |
> 1,000,000 Cycles |
|
Coil Voltage Available (Us) (Rectifier board required for A.C.) |
6 - 240V |